| Input
Modes,Featutes |
Value
Range |
|
| Totaliser |
| A+B,A-B,Direction,Quad |
0..........99999 |
| Preset
Value used for colour switching |
0..........99999 |
|
| Position
Indicator |
| Quad |
-19999......99999 |
| Upper
and Lower Range Limits |
-19999......99999 |
| Set
Value |
-19999......99999 |
| Option:Linear
Output,Scalable,Isolated |
0/4-20
mA,0/1-5 V,0/2-10 V |
|
| Rate
Meter |
| A,A/B,1/A
(displays the impulse duration) |
0.....99999 |
| Extended
Rate Calibration Factor |
0.0001...99999 |
| Upper
and Lower Range Value |
0.....99999 |
| Display
refresh and Zero display time |
0.1
... 10 sec |
| Minimum
impulses for display start |
1..99
|
| Alarm
suppression during startup, hold function |
0...99
sec |
| Option:Linear
Output,scalable,insulated |
0/4
- 20 mA, 0/1-5 V,0/2-10 V |
|
| Rate
Meter+ Totaliser |
| A+B,
A - B,Direction,Quad |
0.....99999 |
| Totaliser |
0.....99999 |
| Extended
Rate Calibration Factor |
0.0001...99999 |
| Upper
and Lower Range Value |
0.....99999 |
| Display
refresh and Zero display time |
0.1
... 10 sec |
| Minimum
impulses for display start |
1..99
|
| Alarm
suppression during startup, hold function |
0...99
sec |
| Option:Linear
Output,scalable,insulated |
0/4
- 20 mA, 0/1-5 V,0/2-10 V |
|
| Preset
Counter |
| A+B,
A - B,Direction,Quad |
0.....99999 |
| 1
or 2 Presets (P 1 as absolute Preset or Prewarm) |
0.....99999 |
| Up/down
with or without auto reset mode |
0-
> P2, P2 -> 0 |
| Out
1 and Out 2 seperately programmable |
latch
or 0.01...99.99 sec |
|
| Batch
Counter |
| A+B,
A - B,Direction,Quad |
0.....99999 |
| Up/down
with or without auto reset mode |
0-
> P1, P1 -> 0 |
| Preset,Batch
Preset, Totaliser |
0....99999 |
| Out
1 and Out 2 seperately programmable |
latch
or 0.01...99.99 sec |
|
| Preset
Time Counter |
| Time
formats programmable |
9999.9
s,9999.9 m, 9999.9 h,mmm:ss, hhh:mm |
| time
preset with output signal |
0.....99999 |
| Count
direction up/down |
0-
> P1, P1 -> 0 |
| Count
Mode |
Single,Accumulating |
|
| Terminals |
|
| Count
Inputs |
| Active
Edge |
NPN
or PNP programmable:capable ofTTL:30 V DC max |
| With
PNP |
High
>=3.0 V, Low < 2.0 V: or open; 10 kOhm to 0V |
| With
NPN |
High
>=3.0 V or open, Low < 2.0 V: or open; 10 kOhm to 0V+ |
| Frequency |
20
Hz, 200 Hz or 10 KHz programmable |
|
| Magnetic
Input |
| Type |
Capacitive:
0.5 to 30 V (only available for rate meters |
|
| Control
Inputs |
| CTRL1 |
NPN:
High >- 3.0 V or open,Low <2.0 V:4,7 kOhm to V+ |
| (Reset
or hold) |
edge
sensitive ; 25 ms min,max 30 V DC |
| CTRL2 |
NPN:
High >- 3.0 V or open,Low <2.0 V:4,7 kOhm to V+ |
| (Progr.security) |
level
sensitive ; 25 ms min,max 30 V DC |
|
| Outputs |
| OUT
1 NPN |
NPN
, open collector: 30 V DC max:100 mA max |
| OUT
2 NPN |
response
time < 75 Us |
| Relay
1 |
Changeover
form C: 240 V AC/3A or 110 V AC /5 A:pull-in |
| Relays
2(opt) |
time
8 ms |
| Auxilary |
9....15
(unregulated V DC), 125 mA max: residual ripple< 0.5 V |
| Power
Supply |
|
|
| Special
Features |
- Display color programmable
- Count Calibrator
0.0001 to 9.9999 as standard
- Preset Lockout
and Reset Disable programmable
- Program Securityvia
CTRL 2
- Hold function on
Tacho version
- Optional Linear
Output
|
| Ordering
Data |
 |