Flexible Counter Family- designed for different applications

You can choose from a selection of eight versions with each version offering special features that are trimmed to match the needs of the target application.

The counters are divided into:

-Counting, Position Indication
-Tachometer, Rate Meter, with or ..without integrated Totaliser
-Preset Counters, Batch Counter
-Time Preset Counter

 

 

Overview
gff
Input Modes,Featutes Value Range
Totaliser
A+B,A-B,Direction,Quad 0..........99999
Preset Value used for colour switching 0..........99999
Position Indicator
Quad -19999......99999
Upper and Lower Range Limits -19999......99999
Set Value -19999......99999
Option:Linear Output,Scalable,Isolated 0/4-20 mA,0/1-5 V,0/2-10 V
Rate Meter
A,A/B,1/A (displays the impulse duration) 0.....99999
Extended Rate Calibration Factor 0.0001...99999
Upper and Lower Range Value 0.....99999
Display refresh and Zero display time 0.1 ... 10 sec
Minimum impulses for display start 1..99
Alarm suppression during startup, hold function 0...99 sec
Option:Linear Output,scalable,insulated 0/4 - 20 mA, 0/1-5 V,0/2-10 V
Rate Meter+ Totaliser
A+B, A - B,Direction,Quad 0.....99999
Totaliser 0.....99999
Extended Rate Calibration Factor 0.0001...99999
Upper and Lower Range Value 0.....99999
Display refresh and Zero display time 0.1 ... 10 sec
Minimum impulses for display start 1..99
Alarm suppression during startup, hold function 0...99 sec
Option:Linear Output,scalable,insulated 0/4 - 20 mA, 0/1-5 V,0/2-10 V
Preset Counter
A+B, A - B,Direction,Quad 0.....99999
1 or 2 Presets (P 1 as absolute Preset or Prewarm) 0.....99999
Up/down with or without auto reset mode 0- > P2, P2 -> 0
Out 1 and Out 2 seperately programmable latch or 0.01...99.99 sec
Batch Counter
A+B, A - B,Direction,Quad 0.....99999
Up/down with or without auto reset mode 0- > P1, P1 -> 0
Preset,Batch Preset, Totaliser 0....99999
Out 1 and Out 2 seperately programmable latch or 0.01...99.99 sec
Preset Time Counter
Time formats programmable 9999.9 s,9999.9 m, 9999.9 h,mmm:ss, hhh:mm
time preset with output signal 0.....99999
Count direction up/down 0- > P1, P1 -> 0
Count Mode Single,Accumulating

Technical Data
Terminals
Count Inputs
Active Edge NPN or PNP programmable:capable ofTTL:30 V DC max
With PNP High >=3.0 V, Low < 2.0 V: or open; 10 kOhm to 0V
With NPN High >=3.0 V or open, Low < 2.0 V: or open; 10 kOhm to 0V+
Frequency 20 Hz, 200 Hz or 10 KHz programmable
Magnetic Input
Type Capacitive: 0.5 to 30 V (only available for rate meters
Control Inputs
CTRL1 NPN: High >- 3.0 V or open,Low <2.0 V:4,7 kOhm to V+
(Reset or hold) edge sensitive ; 25 ms min,max 30 V DC
CTRL2 NPN: High >- 3.0 V or open,Low <2.0 V:4,7 kOhm to V+
(Progr.security) level sensitive ; 25 ms min,max 30 V DC
Outputs
OUT 1 NPN NPN , open collector: 30 V DC max:100 mA max
OUT 2 NPN response time < 75 Us
Relay 1 Changeover form C: 240 V AC/3A or 110 V AC /5 A:pull-in
Relays 2(opt) time 8 ms
Auxilary 9....15 (unregulated V DC), 125 mA max: residual ripple< 0.5 V
Power Supply  
Special Features
  • Display color programmable
  • Count Calibrator 0.0001 to 9.9999 as standard
  • Preset Lockout and Reset Disable programmable
  • Program Securityvia CTRL 2
  • Hold function on Tacho version
  • Optional Linear Output
Ordering Data

Introduction | Infrastructure | Quality control | Proximon Products | Dealers network | Contact Us
Project Division | ABB Drives | ABB PLC | Hengstler Encoder | Hengstler Counter | Application Area



Comments: proximon@vsnl.com
Copyright © 2000 Proximon Controls Pvt. Ltd.