Circular
/ linear motion is sensed by Inductive Proximity Sensor. When
flag is passed through the sensing face of proximity sensor,
pulses are produced. These pulses are fed to the Zero Speed
Monitor. These pulses are then compared with reference comparator.
Whenever speed drops below the set value, digital comparator
detects the same and output relay is switched on.
|
|
Supply Voltage |
230 V AC ± 15 %
110 V AC ± 15 %
24 V AC ± 15 % |
|
Speed Range |
1-10 / 10-100 / 100-1000 / 5-50 / 50-500 / 500-5000 |
|
Hysterisis |
5% of the set value. |
|
Repeat Accuracy |
Within ± 1 % |
|
Speed Setting Accuracy |
Within ± 15 % of designed value. |
|
Contact Rating |
5A / 240 V AC for resistive load. |
|
Operating Temperature |
60o C maximum |
|
Protection |
IP55 |
|
No.
of flags
|
|
RANGE
|
1 - 10
|
5 50
10 - 100
|
50 500
100 - 5000
|
500 5000
|
|
NO. OF FLAGES
|
8
|
4
|
2
|
1
|
|
| On
powering the Zero Speed Monitor; output relay instanteneously
gets on. If the system speed reaches the set value within the
initial by-pass delay period, the relay remains ON. Thus it
keeps the contactor in ON condition to keep the system motor
ON. Now, after initial by-pass delay period, at any time the
system speed drops below the set value; the output relay gets
OFF & in turn switches OFF the contactor. |
| Zero
Speed Monitor is mainly useful for material handling systems,
conveyors, bucket elevator, pick & place mechanism, crushers,
Industrial mixers, disintigrator mills, punching machines, chain
drives & other rotating machines. It can also be used as
overload detector, stall detector to protect AC/DC motors, precision
machine and machines drives. |
- Zero
Speed Monitor is a maintenance free system.
- Variable
initial by-pass delay avoids faulse tripping.
- Wide
speed sensing range is available.
- Robust
cast aluminium enclosure with IP55 protection, suitable for wall mounting.
- LED
indication for power ON, relay ON, speed pulses.
|